SIS Operation, cont’d

This message means that the switcher requires an administrator or user level password before it will perform the commands entered via this link. The switcher repeats the password message response for every entry other than a valid password until a valid password is entered.

Login Administrator

Login User

The switcher initiates the login message when a correct administrator or user password has been entered. If the user and administrator passwords are the same, the switcher defaults to administrator privileges.

MKP Error Responses

When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E24 — Privilege violation (Ethernet, Extron software only)

E99 — Invalid or no response from target switcher

Using the Command/Response Table

The command/response table begins on page 4-8. Lower case letters are acceptable in the command field except where indicated for the gain and attenuation commands. The table below shows the hexadecimal equivalent of each ASCII character used in the command/response tables.

ASCII to HEX Conversion Table

Space

The MKP always redirects a subset of valid matrix switcher- specific SIS commands on its Ethernet port and, if configured in pass-through mode, on its Switcher RS-232 port.

It is not the purpose of this manual to define in detail the passed-through matrix switcher-specific SIS commands. Refer to the applicable matrix switcher’s manual.

Symbols are used throughout the tables to represent variables in the command/response fields. Command and response examples are shown throughout the MKP SIS commands table.

4-4

MKP 2000 Remote Control Panel • SIS Operation