Command/response table for MKP SIS commands (continued)

Command

ASCIICommand

Response

Additional description

 

(host to MKP)

(MKP to host)

 

 

 

 

 

 

 

 

 

 

IP setup (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set Daylight Savings Time

Esc

,

X16

CX

Ipx

X16

 

Set the switcher to display the local time as

 

 

 

 

 

 

 

 

Daylight Savings Time (+1 hour) in summer

 

 

 

 

 

 

 

 

months.

 

 

 

 

 

 

 

 

 

SIS Operation,

Remote Control Panel • SIS Operation

Read Daylight Savings Time

Set DHCP on or off

Read DHCP status

Set MKP IP address

Read MKP IP address

Read hardware (MAC) address

Set subnet mask

Read subnet mask

Set gateway IP address

Read gateway IP address

Set target (switcher) IP parameters

Esc CX

Esc X1 DH

Esc DH

EscX17 CI

Esc CI

Esc CH

EscX17 CS

Esc CS

EscX17 CG

Esc CG

EscX17 — or —

X16

Idh X1

X1

Ipi X17

X17

X18

Ips X17

X17

Ipg X17

X17

X19 SI

Sip X17 , X18 , X19

cont’d

The set target IP parameters command can be issued with either the X17 or the X19 regardless of which variable is entered.

Read target (switcher) IP parameters

 

SI

 

 

,

 

 

,

 

Esc

X17

 

X18

X19

Set administrator password

 

 

 

CA

Ipa

 

 

 

Esc

X20

 

X20

Clear administrator password

 

•CA

Ipa•

Esc

variable, but not both. The response is as shown

MKP 2000

Command/response table for MKP SIS commands (continued)

Command

ASCIICommand

Response

Additional description

 

(host to MKP)

(MKP to host)

 

 

 

 

 

 

 

 

 

 

IP setup (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read administrator password

Esc

CA

X20

 

 

 

 

 

 

 

 

 

 

 

 

Set user password

 

 

 

CU

Ipu

 

 

 

Esc

X20

X20

 

When you have connected multiple MKPs to control a switcher through a primary MKP control panel, do not set a user password on the primary MKP.

Remote Control Panel • SIS Operation 4-11

Clear user password

Read user password

Switch web page priority

Read web page priority

Set verbose mode

Read verbose mode

Read connection’s security level

Esc

•CU

Ipu•

 

 

CU

 

 

 

 

 

 

 

 

Esc

 

X20

 

 

 

 

 

 

 

 

 

Cpag

Iwp

 

 

 

Esc

 

X21

X21

 

 

Cpag

 

 

 

 

 

 

 

Esc

 

X21

 

 

 

 

 

 

CV

Vrb

 

 

Set MKP to report changes from other sources.

Esc

X1

X1

 

CV

 

 

 

 

Read the verbose mode.

Esc

 

X1

 

 

 

CK

 

 

 

 

Esc

 

X10

 

 