Installation

CAUTION

Installation and service must be performed by

 

authorized personnel only. UL Listed electrical

 

boxes are recommended. See UL Requirements

 

for Wall Box Installation on the next page.

The MKP 2000 remote control panel should be installed in a standard, 2-gang electrical wall box (figure 2-1). Figure 2-1 shows the MKP installed in a wall. This could also be in a desk, a podium, or any other convenient location.

The procedures provided here assume that the electrical wall boxes and the cables have been installed for the system. Rear Panel and Side Panel Connections, starting on page 2-8 provides guidance for terminating the cables.

MKP Installation Overview

To install an MKP 2000 remote control panel, follow these steps:

1Disconnect power from the matrix switcher and all MKPs in the system.

2Prepare the site: cut a hole in the wall/furniture, install the electrical box or mud ring, and prepare the cables. Instructions are included in this manual and/or with the wall box. See Preparing the site, installing the mud ring or wall box in this chapter.

3Connect the cable between the MKP and the

matrix switcher. See Rear Panel and Side Panel Connections on page 2-8.

4Connect power cords to the MKP and the matrix switcher.

5Test the MKP’s ability to communicate with the matrix switcher.

6Disconnect power from all the devices.

7Mount the MKP into the electrical box or to the mud ring. If using a wall box, see Mounting the control panel to the mud ring or wall box in this chapter.

8Restore power to the devices.

UL Requirements for Wall Box Installation

The following Underwriters Laboratories (UL) requirements pertain to the installation of the MKP 2000 into a wall or furniture (figure 2-1).

 

 

3

 

 

2

 

OUTPUT

 

1

6

INPUT

 

5

 

R

4

9

TAKE

 

8

 

 

 

7

CANC

EL

 

0

 

0

 

BACK

 

 

 

200

 

 

 

MKP

Figure 2-1 — MKP mounted in a wall box

1.

These units are not to be connected to a centralized DC

 

power source or used beyond their rated voltage range.

2.

These units must be installed in UL listed junction boxes.

3.

These units must be installed with conduit in accordance

 

with the National Electrical Code.

Installation Procedures

The MKPs are mounted into a wall, furniture, or any other convenient location. Follow the instructions appropriate to the mounting option you have selected.

CAUTION

The control panel must be installed into an

 

Underwriters Laboratories (UL) approved electrical

 

wall box.

When installing MKP control panels, you must conform to all national and local electrical codes.