Mounting the Switcher

UL requirements

The following Underwriters Laboratories (UL) requirements pertain to the installation of the MVX into a rack (figure 2-1).

1. Elevated operating ambient temperature — If the equipment installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the MVX in an environment compatible with the maximum +122 °F (+50 °C) ambient temperature (Tma) specified by Extron.

2. Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.

3. Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.

4. Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5. Reliable earthing (grounding) — Maintain reliable grounding of rack- mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips).

Mounting instructions

The MVX VGA A matrix switchers are housed in a rack-mountable,

2U (MVX 128 VGA A) or 3U (all other models) high metal enclosures with mounting flanges for standard 19" racks. If desired, rack mount the switcher as follows:

1.

Insert the switcher into the rack, aligning the holes in the mounting bracket

 

with those in the rack.

2.

Secure the switcher to the rack using the supplied bolts.

2-2 MVX VGA A Matrix Switchers • Installation