Extron electronic MVX VGA A 61 - RS-232/RS-422 and baud rate selection, Preliminary, Baud rate

Models: MVX VGA A

1 107
Download 107 pages 1.84 Kb
Page 62
Image 62
Baud rate:

3. To change a value, press and release the button that relates to the desired value (figure 3-61).

Press and release the button(s) to configure the port as follows:

Baud rate:

 

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

Serial protocol:

 

RGBHV — RS-232

Audio — RS-422

The selected LEDs blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

CONTROL

I/O

ENTER PRESET VIEW ESC

RGBHV AUDIO

Serial protocol: = Lit LED, Figure 3-61 — RS-232/RS-422 and baud rate selection = Blinking LED

Figure 3-61RS-232/RS-422 and baud rate selection

4. Press and release an input or output button to exit Serial Port Configuration mode (figure 3-62).

Press and release an

CONTROL

I/O

input or output button.

 

 

5

ENTER PRESET VIEW ESC

RGBHV AUDIO

 

All Control LEDs return to the unlit state.

 

Each I/O LED returns to its previous state.

Figure 3-62 — Exit Serial Port Configuration mode

NThe switcher requires some time to save the new serial port settings. Wait at least 5 minutes before removing power from the switcher, or the settings may be lost.

MVX VGA A Matrix Switchers • Operation 3-39

PRELIMINARY

Page 62
Image 62