Extron electronic PVS 305SA Pull the cables at the input locations, Signal Cable, Label color

Models: PVS 305SA

1 46
Download 46 pages 10.52 Kb
Page 22
Image 22
2. Pull the cables (at the input locations)

Installation — Stage Two, cont’d

2. Pull the cables (at the input locations)

The following cables need to be installed:

CAT 5 cables for signal transmission from the A/V wall plates to the PVS 305SA

NFor PVT RGB D and PVT RGB D Plus wall plates, two CAT 5 signal cables for each input are needed.

Maximum distance from the PVS 305SA to the Wall plates is 100 feet.

The optimum distance is between 50 and 75 feet. Minimum distance is 15 feet.

The CAT 5 cables supplied are terminated to the TIA 568A standard. Other CAT 5 cables can be used if they are TIA 568A or 568B standards and terminated to the same standard at both ends.

CAT 5 cables (not included) for MLC network connection

PoleVault switcher communication cable from the MediaLink controller (MLC PW/RS-232/VC, 50’, part # 26-626-50)

Projector communication cables from the MediaLink controller (IR Serial Comm, 50’, part # 26-621-50)

a.Drill cable pathways through any obstructions (e.g., wall caps, fire-breaks, or horizontal studs).

b.Label the CAT 5 signal cables at both ends with the supplied labels.

c.Pull the cabling through the wall from the ceiling space down to the location of the transmitters and other wall devices, and out through the openings.

TSecure cables with cable clamps to provide strain relief.

Trim back the outer foil shield to the point where the cable exits the cable clamp, and insulate exposed cable shields with heat shrink to reduce the chance of short circuits.

Both braided and foil shields should be connected to an equipment ground at the other end of the cable.

NOTE Fasten the colored section to the cable first, then wrap the clear section around it.

RGB #1A

2b Use the supplied labels for clear cable identification during installation.

Signal Cable

Label color

 

 

RGB 1A (Input 1 RGB)

Orange

 

 

RGB 1 B (Input 1 RGB)

Orange

 

 

RGB 2A (Input 2 RGB)

Yellow

 

 

RGB 2B (Input 2 RGB)

Yellow

 

 

RGB 3A (Input 3 RGB)

Magenta

 

 

RGB 3B (Input 3 RGB)

Magenta

 

 

RGB 4A (Input 4 RGB)

Light Green

 

 

RGB 4B (Input 4 RGB)

Light Green

 

 

Video 3 (Input 3 Composite Vid)

Dark Green

 

 

Video 4 (Input 1 Composite Vid)

Red

 

 

2c Pull the cables at each location.

2-11 PoleVault Systems Installation • Installation — Stage 2

Page 22
Image 22
Extron electronic PVS 305SA manual Pull the cables at the input locations, Signal Cable, Label color