Extron electronic PVS 305SA Install MediaLink Controller, T Wire stripping lengths, Wire color

Models: PVS 305SA

1 46
Download 46 pages 10.52 Kb
Page 24
Image 24
4. Install MediaLink Controller

Installation — Stage Two, cont’d

4. Install MediaLink Controller

TBefore cabling and installing the MLC 104 IP Plus, locate and write down the MAC address of the device for configuring the IP address. The 12 character alphanumeric address (e.g., 00-05-A6-03-9G-H4) can be found on a label on the side of the controller.

TThe length of exposed wire is critical to avoid transmission problems. Ensure the lengths given here are adhered to when stripping the cables for connection.

NIf a drain wire is used, both ends of the wire must be covered by heat shrink to avoid accidental grounding.

a.Connect the MLC power and RS-232 control cable (part # 26-626-50) as shown.

NThe MLC 104 IP Plus is powered from the PVS 305SA. DO NOT connect an external power supply to the MLC 104 IP Plus unless installing an optional secondary control panel.

Wire Bared

 

 

3/16"

 

 

 

Heat Shrink on

 

(5 mm)

 

Outer Jacket to

 

Max.

 

Inner Conductor

 

 

 

 

 

Transition

 

 

 

 

Heat Shrink on

Drain Wire

7/8"

T Wire stripping lengths (22 mm)

T Wire stripping lengths

RS-232/MLC/IR

Tx Rx IR

+12V

A B C D E

PVS 204SA Switcher's rear panel RS-232/MLC/IR port

Heat Shrink over Drain Wire

From MLC 104 IP Plus

Wire color

To PVS 305SA terminal

terminal

 

 

 

 

 

 

 

 

 

A - (Rx on the MLS port)

White

A - (Tx on the RS-232 port)

B - (Tx on the MLS port)

Violet

B - (Rx on the RS-232 port)

 

 

 

 

 

MLS RS-232 Ground

Drain wire

D - Ground

 

 

 

 

 

 

 

 

 

 

Power Ground

Black

D - Ground

 

 

 

 

 

 

 

 

 

 

12 V In

Red

E - +12 V

 

 

 

 

 

+12 VDC

Ground ( From MLC 104 IP Plus)

Ground (Wire color )

BReceive (Rx) To PVS 305SA terminal Transmit (Tx) B

A Transmit (Tx) terminal Receive (Rx) A

Heat Shrink

 

 

 

 

 

over Drain Wire

 

 

 

 

 

NOTE If you use cable that has a drain wire, tie

Rx

Tx

GROUND

GROUND

+12VIN

the drain wire to ground at both ends.

Apply heat shrink cover to both ends of the

A

B

 

MLS

 

PWR

wire to avoid accidental grounding.

 

 

RS-232

12V

 

MLC's MLS and

Power ports

4a Connecting the MLC to the switcher

2-13 PoleVault Systems Installation • Installation — Stage 2

Page 24
Image 24
Extron electronic PVS 305SA manual Install MediaLink Controller, T Wire stripping lengths, From MLC 104 IP Plus, Wire color