Troubleshooting

Problem

Possible Cause

 

Solution

 

 

 

During data

The Falcon was removed from

Replace the terminal in the dock, or replace the serial

communication, no data

the dock or unplugged from host

cable, and retransmit.

was transmitted, or

PC during communications.

 

 

transmitted data was

 

 

 

Incorrect cable configuration.

See your System Administrator.

incomplete.

 

 

 

Communication software was

Perform setup as described in the PRG.

 

 

incorrectly installed or config-

 

 

 

ured.

 

 

 

 

 

The Falcon does not accept

The scanning window is dirty.

Carefully wipe the scanning window with a soft, clean

scan input.

 

cloth. Do not use abrasive cleaners.

 

 

 

 

The scanning application is not

Verify that the unit is loaded with a scanning applica-

 

loaded.

tion. See your System Administrator.

 

 

 

 

Unreadable bar code.

Be sure the symbol is not defaced.

 

 

 

 

Distance between exit window

Be sure you are within proper scanning range.

 

and bar code is incorrect.

 

 

 

 

 

 

The Falcon is not programmed

Be sure the terminal is programmed to accept the type

 

for that symbology.

of bar code you are scanning. Try using FF3A to turn

 

 

on maximum defaults, as described in “Programming

 

 

Parameters” in the Falcon 4400 PRG.

 

 

 

 

The Falcon is not programmed

If you are expecting a beep on a good decode and

 

to generate a beep.

don’t hear one, check that the application is set to gen-

 

 

erate a beep on good decode.

 

 

Tap

> Settings > System > Decoding > Gen-

 

 

eral > Audio

 

 

OR

 

 

 

Scan the appropriate bar code from the PRG.

 

 

 

 

Battery is low.

If the scanner stops emitting a laser beam when you

 

 

press the trigger, check your battery level. Refer to the

 

 

PRG.

 

 

 

Note: If the scanner is still not reading sym-

 

 

bols, contact your distributor or PSC Inc.

 

 

 

The UPC/EAN extension

Laser beam only crosses over

Set the Read Verification for extensions (parameter

(supplemental label) is not

base of UPC/EAN label.

0528) to a value lower than the Read Verification for

always scanned.

 

the base label. See the PRG.

 

 

 

 