45

Users Manual

 

Measuring Frequency

3-8

 

Frequency Ranging

3-8

 

Frequency Measurement Rates

3-9

 

Measuring Frequency of Current (100 mA and 10A) Inputs

3-9

 

Frequency Sensitivity Selection

3-9

 

Selecting A Function Modifier

3-10

 

REL (Relative Readings) Modifier

3-11

 

dB (Decibels and Audio Power) Modifier

3-12

 

HOLD (Touch Hold) Modifier

3-13

 

MN MX (Minimum Maximum) Modifier

3-13

 

Using Function Modifiers in Combination

3-13

 

Selecting A Measurement Rate (Rate)

3-14

 

Using the SButton

3-14

 

Using The Compare (Comp) Function

3-16

 

The List and Number Editors

3-16

 

Using the List Editor

3-17

 

Using the Number Editor

3-18

 

Power-Up Configuration

3-19

 

Factory Settings of Power-Up Configuration

3-19

 

Changing the Power-Up Configuration

3-19

 

Calibration

3-20

4

Applications

4-1

 

Introduction

4-1

 

Using the Dual Display

4-1

 

Using Measurement Functions in Combination

4-2

 

Taking Voltage and Current Measurements Using the Dual Display

4-2

 

Response Times

4-4

 

How the Meter Makes Dual Display Measurements

4-5

 

Updating the Primary and Secondary Displays with a Single Measurement

4-5

 

Updating the Primary and Secondary Displays with Separate Measurements 4-5

 

Update Rate in the Dual Display Mode

4-7

 

External Trigger

4-7

 

Thermal Voltages

4-8

 

When Measuring Resistance

4-9

 

Two-Wire Configuration

4-9

 

Correcting for Test Lead Resistance

4-9

 

True RMS Measurements

4-9

 

Effects of Internal Noise in AC Measurements

4-10

 

Calculated (AC + DC) RMS Measurements

4-10

 

Waveform Comparison (True RMS vs. Average-Responding Meters)

4-10

5

Operating the Meter Using the Computer Interface

5-1

 

Introduction

5-1

 

Local and Remote Operations

5-1

 

Preparing the Meter for Operations via the RS-232 Interface

5-2

 

Setting Communication Parameters (RS-232)

5-2

 

RS-232 Print-Only Mode

5-3

 

Cabling the Meter to a Host or Printer (RS-232)

5-4

 

Character Echoing and Deletion

5-4

 

Device Clear Using ^C (CNTRL C)

5-4

 

RS-232 Prompts

5-4

 

Preparing the Meter to be Operated via IEEE-488 Interface

5-5

 

IEEE-488 Operating Limitations

5-5

ii

Page 5
Image 5
Fluke 45 user manual Applications

45 specifications

The Fluke 45 is a versatile and high-precision Digital Multimeter that is designed for a wide range of applications in electrical testing, troubleshooting, and maintenance. Known for its reliability and advanced features, the Fluke 45 is an essential tool for engineers, technicians, and professionals who require accurate measurement capabilities.

One of the standout features of the Fluke 45 is its ability to measure both AC and DC voltage and current. With a maximum input voltage of 1000 volts and current ranges up to 10 amps, users can conduct a variety of electrical tests with confidence. The device is equipped with an intuitive dual display, allowing for simultaneous viewing of multiple measurements. This feature enhances usability during complex diagnostics.

The Fluke 45 also boasts an impressive resolution of 0.1 mV and a basic accuracy of 0.25%, which translates to highly reliable readings. The auto-ranging capability simplifies the measurement process, automatically selecting the appropriate range based on the input signal, thus saving time and reducing user error.

In addition to voltage and current measurements, the Fluke 45 features resistance measurement capabilities, with a range of up to 40 MΩ. This makes it an effective tool for testing circuits, identifying faults, and ensuring the integrity of electrical systems. The continuity test function, complete with a built-in beeper, assists in quickly diagnosing wiring issues.

Another remarkable characteristic of the Fluke 45 is its frequency measurement capabilities, which can measure frequencies up to 1 MHz. This is particularly useful in applications involving signal analysis and troubleshooting oscillators.

Moreover, the Fluke 45 is designed with user convenience in mind. It is lightweight and portable, making it easy to carry around, whether on a job site or in a workshop. The rugged construction, reinforced with high-quality materials, ensures it can withstand harsh conditions often encountered in the field.

To enhance functionality, the Fluke 45 features a data hold function that freezes the displayed measurement for easier reporting. Additionally, it can store data for later retrieval, making it convenient for users who need to compile test results over time.

In summary, the Fluke 45 Digital Multimeter is an advanced instrument that combines precision, versatility, and user-friendly design. Its wide measurement capabilities, high accuracy, and durable build make it an invaluable tool for professionals in diverse electrical and electronic applications. Whether for routine maintenance or complex troubleshooting, the Fluke 45 stands out as a reliable partner in achieving accurate and efficient results.