Fostex MR-8 Moving whole track data, Use the Cursor / keys to select source tracks to be moved

Models: MR-8

1 102
Download 102 pages 8.68 Kb
Page 65
Image 65

MR-8 Owner’s Manual

Moving whole track data

You can move whole data (from ABS ZERO to REC END) of the desired mono or stereo track(s) to the other desired track(s). After the data is moved, the original track(s) is(are) silent.

ABS ZERO

REC END

TRK 1

TRK 2

TRK 3

TRK 4

TRK 5

TRK 6

TRK 7

TRK 8

<Note>

You cannot move track data of a song pro- tected. Release the protection before moving track data.

1)Load the song you want to edit.

2)While the recorder is stopped, press the [MENU] key to enter the menu mode.

The display shows the menu selection screen, in which "System" is highlighted initially.

3)Use the [CURSOR ] key to highlight "Track", then press the [ENTER] key.

The display now shows the track edit menu selec- tion screen, in which "EraseTrack" is highlighted ini- tially.

The display now shows the screen for selecting the source track(s) and destination track(s) of the move operation. "Source Track" selects the move source track(s), while "Dest. Track" selects the move desti- nation track(s).

The current position information is shown at the top of the screen (shown in Bar/Beat base in the screen example below).

flashing

5)Use the [CURSOR /] keys to select source track(s) to be moved.

You can select from among mono tracks (1 through 8) and stereo pair tracks (1/2, 3/4, 5/6 and 7/8).

6)Use the [CURSOR ] key to move the cursor to the option for "Dest.Track".

7)Use the [CURSOR /] keys to select the destination track(s).

If you select a mono track for the move source in step 5 above, you can select a mono destination track. If you select stereo pair tracks for the move source in step 5 above, you can select stereo pair destination tracks.

<Note>

You cannot select the same track(s) for the move source and destination.

8)Use the [CURSOR ] key to move the cursor to "ENTER" on the screen, then press the [ENTER] key.

The display shows "Please Wait !", immediately followed by "Completed!" when the MR-8 completes the move operation.

<Note>

If you want to cancel the move operation, move the cursor to "[CANCEL]" on the screen, then press the [ENTER] key.

4)Use the [CURSOR ] key to highlight "MoveTrack", then press the [ENTER] key.

65