Chapter 4: Basic connections

Power connection

The [DC IN] connector (XLR-4-32 type) on the left side panel is used for operating the unit on the optional AC adaptor or an external battery. The PD606 also pro- vides the [DC OUT] connector for supplying DC-12V to an external device.

External device

1

2

3

4

5

6

 

 

 

ANALOG LINE OUT

 

 

ADJUST

DC-OUT

 

 

 

DC-IN

 

 

 

12-24V

12-24V

ST BUS OUT

 

 

 

(0.5A MAX)

 

 

 

 

 

USB

 

 

 

 

 

HOST

 

 

 

 

PC

KYBD

 

 

 

Optional AC adaptor, etc.

3

1

4

 

1

 

 

 

 

 

 

 

4

2

 

3

2

 

 

 

 

 

 

 

 

DC OUT

 

 

DC IN

1

GND

 

1

GND

 

 

 

 

 

2

NC

 

2

NC

3

NC

 

3

NC

 

 

 

 

 

4

DC12~24V

 

4

DC12~24V

<Notes>

The [DC OUT] connector can deliver up to 0.5 ampere electric current at DC 12V to 24V. Only connect a device which meets this requirement.

We strongly recommend using the [DC OUT] connector while you are operating the PD606 on the AC adaptor (or an external battery). If you use the [DC OUT] connectors to supply the power to an external device while the PD606 runs on the battery, the battery power is exhausted quickly.

Location Recorder Model PD606