Chapter 5: Recording/Playback

<Note>: When "DIGI" (or "WORD" or “VIDEO”) is selected but the unit does not re- ceive a correct digital (or word or video) signal or does not lock to the reference signal, "DIGI" (or "WORD" or “VIDEO”) quickly flashes. In such a case, check cable connection, etc.

<Note>: When the system clock is set to "DIGI" or "WORD", the FS of a file to be played back must match the FS setting of the unit. Otherwise, you cannot play back the file. In such a case, make the FS setting of the unit to match the FS of the file.

Sampling frequency and bit length selection [ ]

You can select a sampling frequency and bit length combination.

Available FS/BIT options (default: 48/24)

44.1/16, 44.1/24, 48/16, 48/24, 88.2/24, 96/24, 176.4/24, 192/24

You can select a sampling frequency and bit length combination also via the "Record FS&Bit" menu item in the "SYS SETUP" menu of the MENU mode (see page 144 for details).

<Note>: The sampling frequency of the digital input signal must match the Fs/Bit setting of the PD606.

<Note>: If you change the FS/BIT setting during recording, the new setting is not valid until recording stops.

<Note>: The relation between the number of recording tracks and the Fs/Bit setting is shown on page 84.

TC generator mode setting (TC recording mode) [ ]

You can select the recording mode of the LTC generated by the internal TC generator or external time code.

Available TC recording mode options (default: Rec-Run)

FREE (Free Run), Rec-R (Rec-Run), 24H-R (24H-Run), EXT (Ext Run)

You can also select the TC recording mode via the "Gen mode" menu item in the "TC SETUP" menu of the MENU mode (see page 183).

<Note>: You can set the default LTC start time via the "Default LTC Start" menu item in the "TC SETUP" menu of the MENU mode (see page 190).

Clock pull up/pull down setting [ ]

You can make the pull up/pull down setting of the sampling clock/internal TC frame rate when the clock reference is set to "INT".

Available pull up/pull down options (default: 0.0%)

+0.1%, 0.0%, -0.1%