CHAPTER 3 Work before Operating System Installation 3.3 Connection and Setting of MMB

3.3.9Set up of Alarm E-Mail

Set up the following for Alarm E-Mail.

-Whether to notify through E-Mail, when an error occurs during operation.

-Error level and notification destination at the time of notifying.

For the backup of the set up information, see 3.5 Storage of the configuration information”.

Note

To set up the above mentioned items, log in to Administrator privileges ‘.

Operations

1.Click [Network Configuration]-[Alarm E-Mail].

→ [Alarm E-Mail] window is displayed. For details on [Alarm E-Mail] Window, see “1.5.11 [Alarm E-Mail] window” of PRIMEQUEST 2000 series Tool Reference (C122-E177EN).

FIGURE 3.10 Example of [Alarm E-Mail] Window

2.Enter required items.

Remark

When transmitting [Alarm E-Mail], [From] address to be transmitted to SMTP server is as follows.

-When [Use envelope “from” address] checkbox is on,

The address set up in [From] of [Alarm E-Mail] window becomes [From] address to be transmitted to SMTP server.

-When [Use envelope “from” address] checkbox is off (initial set up)

Following [From] address is transmitted to SMTP server according to the format of [Hostname], set up in [Virtual IP Address]-[Hostname] in [Network Configuration]-[Network Interface] window.

-In FQDN format: root@[Hostname]

-Except in FQDN format: root@localdomain.localdomain

Mail address set up in [From], is used as [From] address of the mail to be transmitted to mail receiver ([To]).

-When FQDN is specified in SMTP Server name, DNS Server needs to be set up. DNS Server can be set up