
CHAPTER 4 Installation of Operating System and bundled software 4.2 Procedure to install Windows in SAN/iSCSI storage device
ROM”.
-For the UEFI Install:
-Set [Device
-Set [Device
3.BIOS is set to recognize LUN of FC card.
For the settings of FC card, Converged Network Adapter and NIC for iSCSI Boot, see PRIMEQUEST 1000/2000 Series SAN Boot Environment Configuration Manual
4.The partition settings in MMB are confirmed after the internal HDD/SDD of PRIMEQUEST is removed.
-SB/IOU configuration is set
See “3.4.1 Setting the partition configuration” - Console redirection is set
See “3.4.6 Settings of Console Redirection”
-Video redirection: Enable
-Virtual media: Enable
-Various modes are set
See “3.4.5 Various mode settings”
5.Only LUN which becomes the installation target of SAN storage device is connected to the partition of
PRIMEQUEST.
For the settings of SAN storage device, see “Attached manual in the SAN storage device”.
6.I/O space is allocated in FC card of the boot path target and SAS RAID controller, RAID card. For the allocation of I/O space, see “5.5.1 How to use sadump (Linux)” and “3.4.5 Various mode settings” of PRIMEQUEST 2000 series Administration Tool Reference
4.2.2Preparation for installation
The following preparations are done.
1.The following disk images should be prepared. Media of Windows operating system
2.FC cable is made a single path (Connection of only 1 FC cable).
4.2.3Installation of operating system
Operating system installation by SVIM is explained.
There are the following types in the operating system installation by SVIM. For the detailed procedure of the respective modes, see ServerView Suite ServerView Installation Manager.
TABLE 4.1 Operating system installation by SVIMMode | Function Overview | Objective |
Quick | The operating system can be installed in the state recommended by | This mode is used when |
Mode | Fujitsu by only executing the required minimum settings. | operating system is easily |
|
| installed. |
Guide | It is set according to wizard set up information. The information that was | This mode is used for |
Mode | set, is saved in a configuration file and can be used at the time of re- | advanced setting of RAID and |
| install | operating system. |
All the inserted windows are examples of display and the contents displayed by the system configuration, etc. are different.
Operations
1.Make the settings by which the ServerView Suite DVD is booted from the virtual media for the partition.
For settings, see“1.6.2 Remote control operation (BMC)” of PRIMEQUEST 2000 series Administration Manual
48