CHAPTER 4 Installation of Operating System and bundled software

4.4Procedures to install RHEL in SAN storage device

a.After turning on the power supply of the partition, while the FUJITSU logo is displayed, press any key (such as [Space] key) except [Enter] key and the Boot Manager front page is displayed.

b.The menu is selected on the Boot Manager front page in the following order. [Boot Maintenance Manager]- [Boot Options]-[Change Boot Order]-[Change the order]

c.UEFI:Fujitsu Virtual CDROMx xxx is set on the top step.

For details on the setting method of boot order, see “■ Change Boot Order of “3.5.2 [Boot Options] menu” of

PRIMEQUEST 2000 series Tool Reference (C122-E177EN).

d.[Commit Changes and Exit] - [Reset System] is specified and the partition is rebooted.

3.After a period of time, the language selection window is displayed. In case of English, select “English”.

4.In initial display window, click [Next] button without setting anything.

5.Select [Deployment] in [Welcome ServerView Installation Manager] window.

6.Select installation mode, select operating system to be installed and set the operating system.

Remark

The IP address of LAN cannot be set in setting operating system. Set IP address after installing the operation system.

7.Click [Start installation]. The installation is started.

8.Replace with the installation medium of operating system according to the instructions of SVIM.

4.4.4Configuring Bundled Software after Installation

Bundled software is configured after installing the operating system.

1.The trap destination from the partition is configured.

Remark

Configuring of the trap destination can be checked by using standard trap for SNMP service. For details, see 6.5.2 Set up of SNMP”.

2.The trap destination and Mail destination through MMB are configured.

In linkage with operations management software, it is configured only if necessary.

-Configuring SNMP trap destination through MMB See 6.5.2 Set up of SNMP

-The report destination and the filter are set when Alarm E-Mail is configured. See 3.3.9 Set up of Alarm E-Mail

3.OneCommand Manager is installed while installing FC card.

a. By executing the following command, the libnl package information is displayed. Confirm that libnl is installed.

#rpm -qi libnl

If libnl is not installed, search libnl package in installation media of distribution, and install libnl package by executing the following command.

#rpm -ivh libnl-<version>-<release>.<arch>.rpm

Remark

Read the part of <version>, <release>, <arch> properly.

b.Download the driver/utility of MC-0JFC31/31B/41/41B/91/91B/A1/A1B from the following URL. http://support.ts.com/

Note

Though PRIMERGY is described in the downloaded binary, driver/utility can be used by the PRIMEQUEST 2000 series.

56