7.2Sense Data Analysis

7.2.1Error information indicated with sense data

Table 7.1 lists the definition of sense data. For details of sense data, refer to Chapter 5 “Sense Data Error Recovery Methods” of the SCSI Logical Interface Specifications.

Subsection 7.2.2 onwards explain troubleshooting using sense data.

Table 7.1 Definition of sense data

 

Sense data

 

 

 

 

 

 

Sense

Additional

Additional

Definition

key

sense code

sense code

 

 

 

qualifier

 

 

 

 

 

00

00

00

Operation was normal.

 

 

 

 

3

0C

03

A write to a disk terminated abnormally.

 

 

 

 

4

32

00

Failed to allocate the alternate block in the alternate processing.

 

40

xx

An error occurred in power-on self-diagnosis.

 

C4

xx

An HDD error occurred.

 

 

 

 

1

1x

xx

A disk read error occurred.

3

1x

xx

A disk read error occurred.

 

 

 

 

E

1D

00

Data discrepancy found by VERIFY command byte check.

 

 

 

 

5

2x

xx

An SCSI error, such as an invalid operation code, occurred.

 

90

00

The RESERVE or RELEASE command cannot be executed

 

 

 

because the SCSI ID of the initiator was not posted in the

 

 

 

SELECTION phase.

 

 

 

 

4 or B

44

xx

A hardware error occurred inside the HDD.

 

 

 

 

B

47

xx

A parity error occurred in the SCSI data bus.

 

48

00

Initiator Detected Error message was received.

 

49

00

An uncounted or inappropriate message was received.

 

4D

xx

Before completion of a command, a command with the same tag

 

4E

00

number was issued.

 

An overlap command was issued.

 

 

 

 