Table 2.3 Environmental/power requirements (continued)

 

 

 

 

 

Specification

 

 

Item

 

 

 

 

 

 

MBA3300NC

 

MBA3147NC

 

MBA3073NC

 

 

 

MBA3300NP

 

MBA3147NP

 

MBA3073NP

 

 

 

 

 

 

 

 

 

 

Regulation

 

± 5 %

 

 

 

 

 

 

 

 

 

 

 

Ready (average)

 

 

0.5 A

 

 

 

 

 

 

 

 

 

Power

+5V DC

Peak operating current

 

 

1.5 A

 

Maximum (peak) DC

 

 

 

requirement

 

 

 

 

 

(*6)

 

 

 

 

 

(*5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Peak operating current

 

 

0.79 A

 

 

 

DC (reference) (*6)

 

 

 

 

 

 

 

 

 

 

 

Ripple (+5 V, +12 V)

 

250 mVp-p or less (*7)

 

 

 

 

 

 

 

 

 

(*1) For detail condition, see Section 4.1.

(*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible.

(*3) At random seek write/read and default on retry setting with log sweep vibration.

(*4) At power-off state after installation

Vibration displacement should be less than 2.5 mm.

(*5) Input voltages are specified at the HDD connector side during HDD Idle state.

(*6) Operating currents are values under random W/R operation of full partition at about 220 IOPS.

(*7) High frequency noise (over 20 MHz) is less than 100 mVp-p.

2.1.4Error rate

Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk equally.

(1)Unrecoverable error rate

Errors which cannot be recovered within 63 retries and ECC correction should not exceed 10 per 1016 bits read.

(2)Positioning error rate

Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks.