Important Alert Items
Important Alert Messages
The important alert messages in this manual are as follows:
A hazardous situation could result in minor or moderate personal injury if the user does not perform the procedure correctly. This alert signal also indicates that damages to the product or other property may occur if the user does not perform the procedure correctly.
Task |
| Alert message | Page |
|
|
| |
Installation | Damage |
| |
| Never remove any labels from the HDD or deface them in any way. | 50 | |
| High temperature |
| |
| To prevent injury, never touch the HDD while it is hot. The DE and LSI | 71 | |
| become hot during operation and remain hot immediately after turning off the |
| |
| power. |
| |
| Data loss |
| |
| 1. | The user must not change the setting of terminals not described in this | 75 |
|
| section. Do not change setting status set at factory shipment. |
|
| 2. | Do not change the setting of terminals except following setting pins |
|
|
| during the power is turned on. |
|
|
| • Write protect: Pin pair 9/10 of the CN2 setting terminal |
|
|
| (NP model only) |
|
| 3. | To short the setting terminal, use the short plug attached when the device |
|
|
| is shipped from the factory. |
|
| Damage |
| |
| 1. | Make sure that system power is off before connecting or disconnecting | 82 |
|
| cables. |
|
| 2. | Do not connect or disconnect cables when power is on.(except NC model) |
|
| Damage |
| |
| 1. | Be careful of the insertion orientation of the SCSI connectors. With the | 82 |
|
| system in which terminating resistor power is supplied via the SCSI cable, |
|
|
| if the power is turned on, the overcurrent protection fuse of the |
|
|
| terminating resistor power supplier may be blown or the cable may be |
|
|
| burnt if overcurrent protection is not provided. |
|
|
| When the recommended parts listed in Table 4.2 are used, inserting the |
|
|
| cables in the wrong direction can be prevented. |
|
| 2. | To connect SCSI devices, be careful of the connection position of the |
|
|
| cable. Check that the SCSI device with the terminating resistor is the last |
|
|
| device connected to the cable. |
|
3 |