(1)Gaps (G1, G2, G3)
No pattern is written on the gap field.
(2)PLO Sync
In this field, pattern X'00' in the specified length in bytes is written.
(3)Sync Mark (SM1, SM2)
In this field, special pattern in the specified length in bytes is written. This special pattern indicates the beginning of the data field.
(4)Data field
User data is stored in the data field of the sector. The length of the data field is equal to that of the logical data block which is specified with a parameter in the MODE SELECT command. Any multiple of 4 between 512 and 528 bytes can be specified as the length.
(5)BCRC
It is a
(6)ECC
This is the 400 bits code that allows detection and correction of errors in the data field, which is capable of correcting the single burst error up to 200 bits max. on the fly.
(7)PAD
In this field, pattern X'00' in the specified length in bytes is written. This field includes the variation by rotation and circuit delay till reading/writing.