Specifications
2.1.3 Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
|
| Item |
| Specification | |
|
|
|
|
|
|
Power |
| Average |
| +5 VDC±5% 1.2 A (2.7 A max) (*1) | |
requirements |
|
|
| Ripple requirement 100mV pp | |
|
|
|
|
|
|
Power |
| Ready |
| 3.9 W (typ) (*2) | |
|
|
|
| ||
consumption | Random seek, read or write | 5.8 W (typ) (*2) | |||
|
|
|
|
| |
(Average) | Power save |
| 3.9 W (typ) (*2) | ||
|
| mode |
| Idle mode | 2.0 W (typ) (*2) |
|
|
|
| Standby mode | 1.2 W (typ) (*2) |
|
|
|
| Sleep mode | 1.2 W (typ) (*2) |
|
|
|
|
|
|
Outer |
| With panel |
| 101.6 150.0 25.4 mm | |
dimensions |
|
|
|
| |
|
|
|
|
| |
(W D | H) | Without panel |
| 101.6K148.4K25.4 mm | |
|
|
|
|
|
|
Weight |
|
|
|
| 410 g (with panel) |
|
|
|
| ||
Environmental | Operating |
| Temperature: 5 to 45°C (gradient 15°C /h or less) | ||
requirements |
|
|
| (*3) | |
K | K |
|
|
| Relative humidity: 10 to 85% (No condensation) |
|
|
| Maximum wet bulb temperature: 29°C or lower | ||
|
|
| |||
Idle |
| Temperature: 0 to 50°C | |||
|
|
|
|
| Relative humidity: 10 to 85% (No condensation) |
|
|
|
|
| Maximum wet bulb temperature: 36°C or lower |
|
|
|
|
| |
|
| Transport |
| Temperature: | |
|
|
|
|
| Temperature: |
|
|
|
|
| Relative humidity: 5 to 90% (No condensation) |
|
|
|
|
| Maximum wet bulb temperature: 41°C or lower |
|
|
|
| ||
Installation | Tilt angle |
| |||
|
|
|
|
|
|