XG2600 Hardware Guide
Laser safety
The XG2600 may be installed with optical transceiver modules (SFP+ modules), which emit invisible laser light.
In the USA, these optical modules are certified as Class 1 laser products that conform to the requirements of the Department of Health and Human Services (DHHS) regulation 21 CFR, Subchapter J. This certification is indicated by a label attached to each optical module.
Outside the USA, these SFP+ modules are certified as Class 1 laser products that conform to the requirements of IEC825- 1 (1993) and Amendment11 (1996) of
Even when cables are not connected, invisible laser light may still be emitted from the optical module’s port openings. To avoid possible injury, do not look directly into the optical module’s port openings.
Optical transceiver modules intended for use in the XG2600 must be selected from the Optical Transceiver Approved Vendor List (obtainable from the vendor’s service department).
Notes on Rack Mounting and Connecting a Powerstrip
Warning
If you mount this device on a rack, pay close attention to operation temperature management, physical stability establishment and current leakage. This device must only be mounted on the rack by a qualified engineer with the required knowledge. Failure to follow this may result in electric shock or fire.
•Monitor and control the internal and external temperature and humidity of your rack, so that it does not exceed the range of guaranteed operation temperature and humidity.
•The air intake and exhaust of the device is conducted at the interface side and FAN unit side. Do not block the intake side or exhaust side in order not to prevent airflow when installing.
•Make sure to check the maximum loading capacity of the rack to be used for mounting.
•Check the power supply capability of the installation location.
•If you connect the power cable of this device to a powerstrip, a large amount of current leakage can occur through the ground line of the strip. Make sure to establish a ground connection before connecting to the power. If the power cable is not directly connected to the distribution board, you must use a powerstip with industrial use plugs (The maximum current leakage for this device is 3.5mA).
About Our Green Products
"Green Products" that have passed our strict environment assessment standard are
• Main Features
- Small size/resource saving
- Power saving function
- High rate of recycling
This symbol is attached to the Green Products that passed the Green Product Assessment Standard of Fujitsu. For Fujitsu's environment protection efforts, refer to the following Fujitsu Web site.
URL : http://www.fujitsu.com/global/about/environment/ "Environment Protection Efforts"
13