XG2600 Hardware Guide | Chapter 2 Installation |
|
|
3.Connect optical cable and release the “disable status” of the SFP+ slot.
•In case of using telnet or console
Enter replacing SFP+ slot number in <port>
#online ether <port>
•In case of using www browser
Make the SFP+ slot number at the selective state by "Setting of physical port" of settings menu. Select "Use" of "Use of physical port", and click "Regist" icon.
4.In case ERROR LED was blinking before replacement, confirm that ERROR LED is off after replacement.
Reference User’s Guide "5.41.1.1 offline" (pg.493), "5.41.1.2 online" (pg.494)
48 | Connecting the Equipment |