XG2600 Hardware Guide

Chapter 2 Installation

 

 

Installation Requirements

The product is specifically designed for rack-mounting.

Check-list

Check the following items.

Check Item

Check Result

 

 

Nothing is put on the switch.

Vents are not obstructed.

The switch is not located on the table or not stuck on another switch.

The switch is not located under direct sunshine, near heating appliance, under high humidity or in a dusty area..

The switch is not located on unstable places where vibrating, or tilting.

"For Safe Use of the Product" has been thoroughly read Reference (pg.8)

2.1.2Space Requirements

When installing the switch and providing maintenance, ensure the space below is maintained.

Ensuring the Space for Installation (Maintenance) of the Switch

Internal cooling fans of the switch allow the air intake and exhaust performed at both at the Interface Side and Fan Unit Side. Ensure the indicated space below and do not put anything which avoids airflow.

800mm

Back space for the maintenance

rack

300mm or more

Space for the maintenance/ installation

150mm or more

XG2600

90mm or more

800mm

300mm or more

Space for the maintenance/ installation

19" rack Depth

Front space for the maintenance

19" rack Width

28

Requirements for Installation Environment

Page 28
Image 28