XG2600 Hardware Guide

Chapter 2 Installation

 

 

2.3.3Connecting Twisted Pair Cable / SFP+ Module

Below is how to connect twisted pair cable and SFP+ module.

Use straight cable when connecting with routers and terminals. Use crossing cable in case of cascading connection with other switching HUBs with transmission mode at fixed setting other than auto negotiation.

straight cable

optical cable

crossing cable

Management port of the switch is set auto negotiation enable by default. (However, SFP+ slots only support 10Gbps full duplex mode fixed setting.)

Ports automatically apply to the maximum speed that plugged equipment supports by the auto negotiation function.

100BASE-TX port

: Up to maximum 100Mbps full duplex mode

Connecting Twisted Pair Cable

Insert twisted pair cable to 10/100BASE-TX port until it clicks.

Twisted Pair Cable

Precautions

Usable twisted pair cables are unshielded twisted pair cable (UTP) over category 5E and shielded twisted pair cable (STP).

Discharge twisted pair cable before connecting as twisted pair cable may be charged static electricity. Refer "2.3.1 Discharging Twisted Pair Cable" (pg.42) for discharging method.

45

Connecting the Equipment

Page 45
Image 45
Fujitsu XG2600 manual Connecting Twisted Pair Cable / SFP+ Module