8. MAINTENANCE, TROUBLESHOOTING

8.7Simple Troubleshooting

This section provides simple troubleshooting procedures which the user can follow to restore normal operation. If you cannot restore normal operation do not attempt to check inside the unit. Any trouble should be referred to a qualified technician.

8.7.1 General

 

General troubleshooting

 

 

If…

Then…

you cannot turn on the

check for blown fuse.

power

check that the power connector is firmly fastened.

 

check for corrosion on the power cable connector.

 

check for damaged power cable.

 

check battery for proper voltage output (10.8 to 31.2 V).

there is no response

turn off and on the power. If there still is no response the key may

when a key is pressed

be faulty. Request service.

8.7.2Radar

GD-1920C requires a network radar.

Radar troubleshooting

If…

But…

 

Then…

you pressed the

nothing appears on the

check that the antenna cable

POWER/BRILL key and the

display

 

is firmly fastened.

RADAR TX soft key to show

 

check if radar source is

the radar picture

 

 

correct.

marks, legends appear

no echo appears

check that the antenna cable

 

 

 

is firmly fastened.

the picture is not updated or

check antenna cable.

it freezes

 

for freeze up, turn the display

 

 

 

unit on and off again.

tuning is adjusted

sensitivity is poor

magnetron may need to be

 

 

 

replaced. Contact your dealer.

the range is changed

radar picture does not

try to hit the [+] and [-] keys

 

change

 

again.

 

 

turn the display unit off and on

 

 

 

again.

there is poor discrimination in

adjust A/C SEA.

range

 

 

 

the true motion presentation

reselect true motion mode.

is not working properly

 

check if heading and speed

 

 

 

are input.

the range rings are not

hit the RADAR DISPLY and

displayed

 

 

RINGS soft keys to display

 

 

 

them.