Image 202
Retainer Ring

8. MAINTENANCE, TROUBLESHOOTING

8.4Replacing the Magnetron

When the magnetron has expired, distant targets cannot be seen on the display. When you feel that long range performance has decreased, contact a FURUNO agent or dealer about replacement of the magnetron.

Radar model and magnetron used

Model

Magnetron Type

Code No.

MODEL 1824C

E3588

000-146-866

MODEL 1834C

E3571

000-146-867

MG4004

000-158-895

MODEL 1934C

MAF1421B

000-158-786-10

 

 

MAF1422B

000-146-871

MODEL 1944C

000-158-788-10

 

 

MG4006

000-158-896

MODEL 1954C

MAF1425B

000-158-790-10

MODEL 1964C

M1458F

000-158-780-10

8.5Replacing the Synchro Belt (1824C only)

When the synchro belt of MODEL1824C has worn out, the sweep is not synchronized with antenna rotation, which results in an abnormal picture.

When you suspect that the synchro belt has worn out, contact a FURUNO agent or dealer about replacement. (Type: 40 S2M 266UG, Code No.: 000-808-743)

8.6Trackball Maintenance

If the cursor skips or moves abnormally, you may need to clean the Trackball.

1. Turn the retainer ring counterclockwise 45° to unlock it.

2. Remove the retainer ring and ball.

3. Clean the ball with a soft lint-free cloth, and then blow carefully into the ball-cage to dislodge dust and lint.

4.Look for a build-up of dirt on the metal

rollers. If dirty, clean the rollers using a cotton swab moistened lightly with isopropyl-rubbing alcohol.

5.Make sure that fluff from the swab is not left on the rollers.

6.Replace the ball and retainer ring. Be sure the retainer ring is not inserted reversely.

Note: Trackball maintenance parts are available as below.

Part

Type

Code No.

Retainer ring and ball

MU3721

000-144-645