2. RADAR OPERATION

This chapter covers radar operation, including the ARP (Auto Plotter) function. ARP requires a Model 18x4C/19x4C series network radar equipped with the ARP circuit board.

2.1Radar Display

North marker

 

Guard zone 2

 

 

 

 

 

 

 

 

 

 

 

 

(Head-up, Course-up mode)

 

 

 

 

 

 

 

 

 

 

Cursor

 

 

Heading

 

Range/

Pulselength

 

 

 

 

 

 

 

 

 

 

Heading line

 

 

M: Magnetic

 

range ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T: True

 

interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Presentation

 

3nm

 

 

 

 

°

 

TRAIL 30m

Trail time

12/LP

 

 

 

319. 9

M

mode

H-UP

 

 

 

 

02m30s

Trail elapsed time

Alarm icon

 

 

 

 

 

 

 

 

G1 IN

Guard zone 1

EBL1

 

 

 

 

 

 

 

 

G2 OUT

Guard zone 2

Battery icon

 

 

 

 

 

 

 

 

ES H

Echo stretch

S I

 

 

 

 

 

 

 

EAV L

Echo averaging

Simulation

 

 

 

 

 

 

 

mode

 

M

 

 

 

 

 

 

IR L

Interference rejector

 

 

 

 

 

 

 

 

 

 

Guard zone 1

 

 

 

 

 

 

 

 

VRM2

Range ring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EBL2

 

 

 

 

 

 

 

 

 

 

VRM1

 

 

 

 

 

 

 

 

 

Own ship vector

 

 

 

 

 

 

 

 

 

(ARP-equipped model,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

true vector mode)

Zoom area

 

 

 

 

 

 

 

 

 

Zoom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

window

EBL1 bearing

EBL1

EBL2

 

°

 

 

 

+ 359.9 ˚R

Cursor range

VRM1 range

VRM1 27.0°R

VRM2

327.1

 

R

 

 

 

5.666nm

 

8.212nm

 

 

11.70nm

and bearing

 

 

 

 

 

 

 

 

 

 

 

 

 

EBL2 bearing, VRM2 range

(Cursor position may

 

 

 

also be shown, in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L/L or Loran C TD.)

Radar display

2.2Transmitting, Stand-by

1.Confirm that the network radar is plugged in.

2.Press the DISP key to select a radar display.

3.Press the POWER/BRILL key momentarily.

4.Press the RADAR STBY soft key to highlight TX on its label.

5.Press the RETURN soft key.

When the radar picture is not required, but you want keep it in a state of readiness, press the RADAR TX soft key to highlight STBY on its label.

2-1

Page 30
Image 30
Furuno 1824C manual Radar Display, Transmitting, Stand-by, Radar display