8. MAINTENANCE, TROUBLESHOOTING

Network sounder test (Requires Network Sounder ETR-6/10N, ETR-30N)

Press the NETWORK SOUNDER TEST soft key at the MEMORY I/O TEST menu to test the Network Sounder ETR-6/10N or ETR-30N. The equipment displays network sounder program version number, checks the ROM and RAM, and displays water temperature (appropriate sensor required) and depth. The results of the ROM and RAM check are shown as OK or NG (No Good). For any NG, request service. Press the RETURN soft key to return to the MEMORY I/O TEST menu.

PROGRAM No. 02523060XX

ROM 1

: OK

RAM

: OK

TEMPERATURE: 65.61°F

DEPTH

: 100ft

Machine Status +115

XX = Program Version No.

ETR-30N: 0252310XX.XX

Network sounder test results

ARP test (Requires ARP pcb in Model 18x4/19x4 series network radar)

The ARP test is mainly provided for the service technician. Press the ARP TEST soft key at the MEMORY I/O TEST menu to test the ARP. The results of the ROM and RAM check are shown as OK or NG (No Good). For any NG, request service. Press the RETURN soft key to return the MEMORY I/O TEST menu.

PROGRAM No. 18590271XX

ARP ROM

: OK

ARP RAM

: OK

SPEED

: OK 12.3kt

COURSE

: OK 359.9°

TRIGGER

: OK

VIDEO

: OK

BP

: OK

HP

: OK

MIN-HIT

: 0003

SCAN-TIME

: 0250

MAN-ACQ

: 00

AUTO ACQ

: 00

FE-DATA1

: 000

FE-DATA2

: 000

Machine Status +115

XX = Program Version No.

ARP test results

8-9