2. RADAR OPERATION

2.17.2 Measuring range & bearing between two targets

The procedure which follows shows how to measure the range and bearing between two targets, using the targets “A” and “B” in the figure below as an example.

1.Operate the Trackball to place the cursor on the target “A.”

2.Press the EBL/VRM key to show the EBL/VRM soft keys.

3.Press the EBL1 ON soft key to turn on the EBL1.

4.Press the OFFSET soft key. The origin of EBL1 moves to the cursor position, which is marked with an “X.”

5.Rotate the ENTER knob so the EBL bisects the target “B.”

6.Push the ENTER knob, then press the VRM1 ON soft key.

7.Rotate the ENTER knob to place the VRM1 on the inner edge of the target “B.”

8.Look at the indications for VRM1 and EBL1 to find the range and bearing between the two targets.

To cancel the offset EBL, press the OFFSET soft key.

3nm

319. 9°M

 

12/LP

EBL

H-UP

 

VRM

EBL1

ON

Target B

VRM1

 

ON

Target A

OFFSET

 

EBL2

ON

VRM2

ON

 

EBL1

+ 359.9 ˚R

Bearing and range

VRM1 45.0°R

between target A

7.121nm

11.70nm

 

 

and target B

 

 

Measuring range and bearing between two targets

2-16

Page 45
Image 45
Furuno 1824C manual Measuring range & bearing between two targets, Measuring range and bearing between two targets