1. MOUNTING

Mounting of transducer tank

Install the transducer tank referring to the hull unit outline drawings at the back of this manual.

Note 1: When making a retraction tank locally, the inside diameter of the retraction tank should be φ 190±0.5 as shown in the outline at the back of this manual. If larger, the hull unit may be damaged.

Note 2: Locate the retraction tank so that the center of any two bolt holes is facing the ship’s bow.

a=b

a b

Bow

1.4.4Assembling and mounting of hull unit

The hull unit is shipped as the parts shown in the hull unit kit in the Equipment Lists (page v). Assemble the hull unit as shown in the procedure below.

Note: Confirm the frequency of soundome before mounting by referring to the table below.

Frequency

Specification

 

 

60/153 kHz

There is NO label attached on the dome.

85/215 kHz

There is the label “85/215 kHz” attached

 

 

on the dome.

 

 

 

 

For 85/215 kHz, the label is

 

attached here.

 

Necessary tools

Name

Specification

Remarks

 

 

 

Wrench

For M10 (Hex. size 17 mm)

Recommended: double offset wrench

 

 

 

Wrench

For M20 (Hex. size 30 mm)

 

 

 

 

Pipe Wrench

55 mm

For fixing gland

 

 

 

Ball Wrench

Hex size 4 mm

For fixing the dome

 

 

 

1-10