2. WIRING

2.3Hull Unit

Pass the cables to the 06P0257 Board, through the cable protectors.

J2

06P0257

Fasten glands securely by hand.

Cable from transducer

J1

J3

J1

J2

06S4081

Attach the EMI core RFC-4 (supplied)

*Noteto this cable, and then fix the core to the cable for JI with the cable tie CV-100N (supplied).

Cable from transceiver unit 06S4080

*Note

TB2 +

Power cable 250V-DPYCYS-2.5

-

*Note

06P0243

Power switch

Should always be in up position (ON).

Earth

Connect to ship's earth.

*Note: Fix the braided shield with cable clamp.

Hull unit, inside view

Attaching EMI core RFC-4

2-6

Page 38
Image 38