3.ADJUSTMENTS

3.1General Checks

General checks

Check Item

Check point, Rating

On-keel Installation

Retraction tank level

Off-keel Installation

Within 1 m

Clearance between transducer and bottom of retraction tank when transducer is completely retracted by hand crank

1 cm

Transducer travel

 

 

 

(lowered by hand clank)

 

 

 

Note: For checking purposes, a

 

 

400 travel:

 

 

Minimum 30 cm

clearance of approximately 1 meter

 

 

250 travel:

 

 

is required beneath the bottom of

 

 

 

 

Minimum 22 cm

the transducer.

 

 

 

 

 

 

 

 

 

Transducer heading

Bow mark on the shaft sleeve should face to

 

ship's bow.

Bow

3-1