3. ADJUSTMENT

 

General checks (con’t)

 

 

 

Check Item

 

Check point, Rating

 

 

 

Wiring check

 

All cables are correctly connected.

 

 

All lead wires are tightly fixed with contact pins

 

 

or crimp-on lugs.

 

 

All screws are firmly fastened.

 

 

Cables are firmly secured.

 

 

Cable shields are properly grounded.

 

 

 

Rejecting source of noise and

 

Noise generating machinery (motor,

interference

 

radiotelephone, TV set, etc.) are not placed

 

 

nearby.

 

 

Magnetic devices are not placed in the vicinity of

 

 

display unit.

 

 

 

Earth

 

Each unit is grounded with a copper strap.

 

 

 

Ship’s mains voltage

 

Ship’s mains voltage is stable 12 or 24 VDC.

 

 

 

Watertightness

 

Water should not leak from the main body flange

 

 

or along the main shaft.

 

 

 

3.2Checking TX Frequency

Check the TX frequency after installing the equipment.

1.Press the MENU key to open the menu.

2.Press the cursor pad to select SYS at the top of the menu display.

3.Press ▼ to select GO TO SYS MENU.

 

MENU

COM1

COM2 HORZ VERT ES SHORT-CUT

SYS

 

 

GO TO SYS MENU

 

 

 

 

 

 

YES

NO

 

 

 

 

 

 

 

 

 

 

 

: SELECT

: CHANGE

MENU: END

User menu (SYS)

4. Press ◄ to select YES to display the system menu.

3-2

Page 42
Image 42
Furuno CH300 manual Checking TX Frequency, General checks con’t, User menu SYS