Irradiators

Irradiators

Table 26 lists the various Fusion UV Systems Irradiator models and cooling method.

Table 26. Irradiator Models and Details

System

Power Supply

Irradiator Designation

Cooling Method

 

 

 

 

F300S/

P300M/P300MQ/

I300M/I310M/I310M-D/

Remote cooling (Note 1) 2.8 m3/min

F300SQ

P300MT

I311M/I311M-D

(100 cfm) at 695 Pa (2.8 H2O) inlet

 

 

 

pressure

 

 

 

 

 

 

I300MB/I310MB

K300M Modular Blower

 

 

 

 

NOTE: All air flow specifications assume standard air density of 1.20 kg/m3 (0.075 lbs/ft3). Remote blower specification must be corrected for air density variations at customer site.

Cooling:

I300M/I310M/I310M-D/I311N/I311M-D: Requires a remote pressure blower.

I300MB/I310MB/I310MB-D:

K300M modular blower mounts on top of

 

the irradiator and is powered by the

 

P300M/P300MQ power supply.

Table 27. Power Inputs from P300M/P300MQ/P300MT

Magnetron Power:

695 mA+45mA @ 3900 VDC

 

 

Filament Voltage:

115 VAC

STANDBY

 

 

 

100% Power

85 VAC

 

 

Blower Voltage

2.0 A @ 200-240 VAC

 

 

Reflector:

Polished and brightened aluminum elliptical reflector with protective

 

aluminum oxide coating. Focus is 53.3 mm (2.1 inches) below

 

irradiator base rails.

 

The standard reflector has R500 coating. Optional reflectors have

 

R350 or Dichroic (cold) coatings.

Interlocks:

Photoresistor assembly

 

Air pressure switch

Weight:

12.0 kg (26.5 lbs) with modular blower.

 

7.3 kg (16.0 lbs) without modular blower

Installation, Operation, and Maintenance Manual # 509252 Rev R 123