Table 1. Icons (continued)

Icon

Definition

 

 

CAUTION: Ultraviolet Radiation

This icon identifies instances where damaging levels of ultraviolet radiation may be present. Adequate shielding around the equipment and region must be provided, and personnel should be required to wear goggles with UV certified lenses. All personnel within ten feet of the lamp should wear gloves and long sleeves to protect their hands and arms, and ensure that their legs are covered.

CAUTION: Radio Interference

Fusion lamps operate at a fundamental frequency of 2.45 GHz. The unit may cause interference with some local area networks (LANs) that also operate at this frequency. Please check with your LAN manufacturer for compatibility. Ensure that the equipment is properly maintained and shielded.

CAUTION: Ozone

High concentrations of ozone can cause discomfort, or at sufficiently high levels be dangerous. Although Fusion lamp systems make ozone at a level that could barely be detected by odor and at a factor of five below the level of 0.1 parts per million allowable for continuous exposure (American Conference of Governmental Hygienists), all Fusion UV Lamp Systems should be exhausted to the outdoors.

CAUTION: Hot Temperature, Do Not Touch

Surface temperatures of the lamp during normal operation may exceed 120o F. Metal components near the lamp will also be hot. Observe appropriate precautions to avoid burns.

14F300S/F300SQ Ultraviolet Lamp System