Power Source

CAUTION: Measure the main single-phase voltage of your plant facilities to ensure that it conforms to the factory-wired operating voltage specified on the equipment label (rear panel of power supply).

Available line voltage should be within 10% of the nominal operating voltage.

Fusion UV equipment must be connected in accordance with local wiring codes. Use applicable standards for wire sizes, fuse sizes, and disconnect box locations. Each power supply requires a separate, fused single-phase circuit with a line disconnect.

NOTE: If a line voltage greater than 230V and a frequency of 50 Hz is used, see the “F300S Relay Coil Resistor Assembly Installation” on page 53 at the end of this chapter.

System Power Connections

F3q0004

Figure 14. Power Supply Front Panel

Listed current ratings indicate current demands during normal full-power operation. Your customer-supplied wiring and circuit breaker or fuses should be sized to allow for heavier current draw at startup. Current ratings are the same for 50 Hz or 60 Hz systems. The recommended power cord to wire to P101 is: