2.Turn the Master POWER switch ON and press the LAMP ON switch.

3.The system will now operate from remote switches. Remote switch functions are virtually the same as front panel switch functions.

Table 13. Remote Switch Functions

Remote Switch

Equivalent Panel

Lamp Status

 

 

Control

Switch Open

Switch Closed

 

 

 

 

 

 

 

Lamp ON

Lamp ON

Standby

Lamp ON

 

 

 

 

Lamp RESET

LAMP OFF/RESET

Default to lowest state

LAMP OFF/RESET

 

 

 

 

Operation with Remote Controls

Table 14. Operation with Remote Controls

Panel Controls on Master

Remote

 

Switches

 

 

 

 

 

 

 

 

Power

Lamp Control

Lamp ON

Lamp Status

 

 

 

 

Off/Reset

S

S

Off/Reset

 

 

 

 

ON

LAMP OFF/RESET

S

LAMP OFF/RESET

 

 

 

 

 

ON

Remote RESET

LAMP OFF/RESET

ON

 

Switch CLOSED

(overrides remote Lamp

 

 

 

ON switch)

 

 

 

 

 

STANDBY

OPEN

STANDBY

 

 

ON

CLOSED

 

 

 

 

 

 

ON

OPEN

 

 

 

 

 

 

 

CLOSED

Lamp ON

 

 

 

 

KEY:

S- Switch position does not matter.

Quick Restart Option (QRO)

The Quick Restart Option (QRO) provides the ability to restart the lamp at any time, even immediately after the lamp has been switched to Standby mode. Thus, the mandatory 18-second restart cycle time associated with routine operation has been eliminated. The QRO may be installed at the time of the P300MQ power supply construction or may be retrofitted into P300M power supplies in the field by trained personnel.

60F300S/F300SQ Ultraviolet Lamp System