Gefen ext-dvikvm-lan user manual Using RS-232, Basic RS-232 connection

Models: ext-dvikvm-lan

1 65
Download 65 pages 49.6 Kb
Page 37
Image 37

Operating the DVI KVM over IP

Using RS-232

The DVI KVM over IP supports RS-232 pass-through, allowing the control of remote RS-232 devices. The Sender and Receiver unit which are being used to pass-through the RS-232 data must be set to the same baud rate as the RS-232 host and client.

In the example below, the Gefen 4x1 DVI Switcher w/ Audio Decoding (Gefen part no. GTV-AUDDEC-N) has been connected to Receiver unit A. This is the RS-232 client. We want to control this product from Sender unit S3, using a laptop PC (RS-232 host). The channel numbers are listed in blue.

Figure 2.6 - Basic RS-232 connection

 

 

DVI Out

Receiver unit

 

LAN

 

 

 

 

 

 

 

 

 

 

 

 

R2

02

Sender unit

DVI Out

Receiver unit

 

 

 

 

 

 

 

 

 

S

 

R

 

12

 

3

 

1

 

Sender unit

 

RS-232 controller (Computer)

12

DVI In

-N

-AUDDEC GTV

RS-232 device (GTV-AUDDEC-N)

 

S

 

 

2

 

Sender unit

 

 

 

09

DVI In

1

 

S

 

 

05

DVI In

 

 

 

As shown in the User Manual for the Gefen 4x1 DVI Switcher w/ Audio Decoding, the following settings are used:

Table 2.1 - RS-232 settings for the Gefen 4x1 DVI Switcher w/ Audio Decoding

Description

Setting

Baud rate

19200

Data bits

8

Parity

None

Stop bits

1

Hardware flow control

None

Confirm that the same RS-232 settings are assigned to both the Sender and Receiver units. Access the Web interface on both the Sender unit and Receiver unit to set the proper RS-232 settings.

In the example, on the following page, we will begin by setting up Sender unit S3.