Operating the DVI KVM over IP

Using RS-232

1.Access the Web interface for the Sender unit.

2.Click the Functions tab.

3.Locate the Serial over IP group and change the RS-232 settings to match the settings of the RS-232 device that is being used. In this case, we need to use the settings from Table 2.1

4.Make sure that the Enable Serial over IP box is checked.

NOTE: If Enable Serial over IP is not checked, then RS-232pass-through will be disabled.

5.Click the Save button in the lower-right corner of the Serial over IP group.

6.The following message will be displayed, at the top of the page, indicating that the new Serial over IP options have been applied.

7.Click the Reboot button near the bottom portion of the page to apply the changes.

If the unit is not rebooted within a certain period of time, the “Reboot for new settings to take effect” will be displayed at the top of the page.

8.Repeat steps 1 through 6 for the Receiver unit.

page 28

Page 38
Image 38
Gefen ext-dvikvm-lan user manual Using RS-232