440V 3-Phase

Serious personal injury could occur if you connect your machine to the power source before you have completed the setup process. DO NOT connect the machine to the power source until instructed to do so.

Wiring

The Model G0501 is prewired for 220V 3-phase operation. If 440 voltage is required, rewire the machine per the instructions on page 12 and fol- low the circuit requirements on this page.

Amperage Draw

The Model G0501 has a 10 HP main motor and a 1 HP scoring motor that will draw the following amps at 440V 3-phase :

Arbor Motor

12.5

Amps

Scoring Motor

1.5

Amps

Circuit Breaker Requirements

Install the machine on a dedicated circuit to reduce the possibility of overloading the circuit and tripping the circuit breaker. If the circuit breaker trips and the circuit is of the correct load capacity, have the circuit inspected by qualified electrician. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.

Circuit Breaker

20 Amp, 3 Pole

Minimum Cord Requirements

For 440V 3-phase operation, use the following type of cord (a cord is not included):

Cord

3 pole, 4 wire

Gauge

12

Plug Type

The plug you install on your cord will depend upon the type of service you currently have or plan to install. We recommend using the following plug and receptacle for your machine on a dedi- cated circuit only (see Figure 1b for an example):

Plug & Receptacle ..................................L15-20

Figure 1b. Typical locking type L15-20 plug and

receptacle.

Your Shop Circuit Capacity

Always check to see if the wires in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same circuit. If you are unsure, consult a qualified electrician.

A fire may occur if your particular electrical configuration does not comply with local and state codes. The best way to ensure compliance is to check with your local municipality or a licensed electrician.