Grizzly instruction manual Rewiring to, To rewire the Model G0501 for 440V opera- tion

Models: G0501

1 96
Download 96 pages 40.55 Kb
Page 14
Image 14

Rewiring to 440V

The Model G0501 can be rewired for 440V oper- ation. This rewiring job consists of disconnecting the saw from the power source, changing the connections on the voltage transformer, changing the overload relays for the cutting motor and scoring motor, and rewiring the cutting motor and scoring motor.

The necessary overload relays for this procedure can be purchased in the Model G0501 440V Conversion Kit by calling our customer service number at (800) 523-4777.

This procedure takes moderate electrical skill and the rewiring job must be inspected by a licensed electrician before the saw is connected to the power source. Also, the motors can be accessed easier for rewiring if the blade is moved to 0˚ (90˚ to table) before beginning.

To rewire the Model G0501 for 440V opera- tion:

1.Disconnect the saw from the power source!

2.Open the electrical panel and locate the volt- age transformer shown in Figure 2.

Scoring

Voltage Motor Relay

Transformer

Main Motor

Relay

Figure 2. Inside view of the control panel.

3.At the voltage transformer, remove the wire that leads to the “220” terminal and connect that wire to the “440” terminal (see Figure 3).

340

480

Voltage Transformer

Figure 3. Wire removed at 220V location and

connected to 440V location.

4.Remove the main motor overload relay (RH- 18/26 21-31A) and replace with the 440V overload relay (RH-18/15 12-18A) that was included with the Grizzly 440V conversion kit. Set the overload relay dial to 13A.

5.Remove the scoring motor overload relay (RH10E/3C 2.4-3.6A) and replace with the 440V overload relay (RH10E/1.7C 1.3-2A) from the conversion kit. Set the overload relay dial to 1.7A.

6.Open the motor cabinet door and remove the motor wiring caps from the main motor and the scoring motor.

7.Rewire the motors as shown on the diagrams that are placed on the inside of the motor wiring caps. Note—The diagram labeled “Higher” is the correct wiring for 440V.

-12-

G0501 Sliding Table Saw

Page 14
Image 14
Grizzly instruction manual Rewiring to, To rewire the Model G0501 for 440V opera- tion