G0601 Circuit Requirements for

220V

The Model G0601 is prewired to operate on a 220V power supply circuit that has a verified ground and meets the following requirements:

Nominal Voltage

220V/240V

Cycle

60 Hz

Phase

3-Phase

Circuit Rating

15 Amps

Plug/Receptacle

NEMA 15-15

G0601 Circuit Requirements for

440V

The Model G0601 can be converted to operate on a 440V power supply. G0601 440V Conversion instructions are provided later in this manual. The intended 440 circuit must have a verified ground and meet the requirements that follow:

Nominal Voltage

440V/480V

Cycle

60 Hz

Phase

3-Phase

Rated Size

15 Amps

Connection

Hardwire with Locking Switch

Grounding Instructions

In the event of certain types of malfunctions or breakdowns, grounding provides a path of least resistance for electric current—in order to reduce the risk of electric shock.

Improper connection of the equipment-grounding wire can result in a risk of electric shock. The wire with green insulation (with or without yellow stripes) is the equipment-grounding wire. If repair or replacement of the power cord or plug is nec- essary, do not connect the equipment-grounding wire to a live (current carrying) terminal.

Check with a qualified electrician or service per- sonnel if you do not understand these grounding requirements, or if you are in doubt about whether the tool is properly grounded. If you ever notice that a cord or plug is damaged or worn, discon- nect it from power, and immediately replace it with a new one.

-14-

Grounding & Plug Requirements

For Model G0442 220V operation: The rec- ommended plug specified for the Model G0442 under Circuit Requirements has a grounding prong that must be connected to the equipment- grounding wire of the power cord. The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances (see Figure 2).

L6-30 GROUNDED

LOCKING

RECEPTACLE

Grounding Prong

is Hooked

L6-30

LOCKING

PLUG

Current Carrying Prongs

Figure 2. Typical L6-30 plug and receptacle.

Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual.

NOTICE

No adapter is available or should be used with this machine. If the machine must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and after reconnection, the machine must com- ply with all local codes and ordinances.

Model G0442/G0601 (Mfg Since 8/10)

Page 16