G0601 Circuit Requirements for
220V
The Model G0601 is prewired to operate on a 220V power supply circuit that has a verified ground and meets the following requirements:
Nominal Voltage | 220V/240V |
Cycle | 60 Hz |
Phase | |
Circuit Rating | 15 Amps |
Plug/Receptacle | NEMA |
G0601 Circuit Requirements for
440V
The Model G0601 can be converted to operate on a 440V power supply. G0601 440V Conversion instructions are provided later in this manual. The intended 440 circuit must have a verified ground and meet the requirements that follow:
Nominal Voltage | 440V/480V | |
Cycle | 60 Hz | |
Phase | ||
Rated Size | 15 Amps | |
Connection | Hardwire with Locking Switch |
Grounding Instructions
In the event of certain types of malfunctions or breakdowns, grounding provides a path of least resistance for electric
Improper connection of the
Check with a qualified electrician or service per- sonnel if you do not understand these grounding requirements, or if you are in doubt about whether the tool is properly grounded. If you ever notice that a cord or plug is damaged or worn, discon- nect it from power, and immediately replace it with a new one.
Grounding & Plug Requirements
For Model G0442 220V operation: The rec- ommended plug specified for the Model G0442 under Circuit Requirements has a grounding prong that must be connected to the equipment- grounding wire of the power cord. The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances (see Figure 2).
LOCKING
RECEPTACLE
Grounding Prong
is Hooked
LOCKING
PLUG
Current Carrying Prongs
Figure 2. Typical L6-30 plug and receptacle.
Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual.
NOTICE
No adapter is available or should be used with this machine. If the machine must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel; and after reconnection, the machine must com- ply with all local codes and ordinances.
Model G0442/G0601 (Mfg Since 8/10)