Grizzly G0601 owner manual System Grounding

Models: G0601

1 64
Download 64 pages 33.93 Kb
Page 43
Image 43

System Grounding

Since plastic hose is abundant, relatively inex- pensive, easily assembled and air tight, it is a very popular material for conveying dust from woodworking machines to the dust collector. We recommend using flexible hose (flex-hose) to con- nect the woodworking machine to the dust collec- tor. However, plastic flex-hose and plastic duct are an insulator, and dust particles moving against the walls of the plastic duct create a static electrical build up. This charge will build until it discharges to a ground. If a grounding medium is not available to prevent static electrical build up, the electrical charge will arc to the nearest grounded source. This electrical discharge may cause an explosion and subsequent fire inside the system.

To protect against static electrical build up inside

anon-conducting duct, a bare copper wire should be placed inside the duct along its length and grounded to the dust collector. You must also confirm that the dust collector is continuously grounded through the electrical circuit to the elec- tric service panel.

If you connect the dust collector to more than one machine by way of a non-conducting branching duct system and blast gates, the system must still be grounded as mentioned above. We recom- mend inserting a continuous bare copper ground wire inside the entire duct system and attaching the wire to each grounded woodworking machine and dust collector.

Always guard against static electrical build up by grounding all dust collection lines.

Be sure that you extend the bare copper wire down all branches of the system. Do not forget to connect the wires to each other with wire nuts when two branches meet at a “Y” or “T” connec- tion.

Ensure that the entire system is grounded. If using plastic blast gates to direct air flow, the grounding wire must be jumped (Figure 57) around the blast gate without interruption to the grounding system.

Plastic Blast

Gate

Copper

Metal Duct

Ground Wire

 

Figure 57. Ground jumper wire when using

plastic blast gates and metal duct.

External Ground Wire

 

Internal

Ground Screw

Ground Wire

 

Flex-Hose

Figure 58. Flex-hose grounded to machine.

We also recommend wrapping the outside of all plastic ducts with bare copper wire to ground the outside of the system against static electrical build up. Wire connections at Y’s and T’s should be made with wire nuts.

Attach the bare ground wire to each stationary woodworking machine and attach to the dust collector frame with a ground screw as shown in Figure 58. Ensure that each machine is continu- ously grounded to the grounding terminal in the electric service panel.

Model G0442/G0601 (Mfg Since 8/10)

-41-