Correcting Phase Polarity (G0601 Only)

This subsection is only provided for troubleshoot- ing. If you discover during the test run that the machine will not operate, or that the impeller spins backward, the power connections may be wired out-of-phase. Without the proper test equipment to determine the polarity of the power source legs, wiring machinery to 3-phase power may require trial-and-error. Correcting phase polarity is simply a matter of reversing the positions where two of the incoming power source wires are connected inside the control box.

NOTICE

If this machine is wired out-of-phase, the motor and impeller will spin in the wrong direction. The efficiency of the dust col- lector will be greatly reduced and will not provide the rated CFM. You must make sure the motor is spinning in the correct direction before placing the machine into full operation. Perform Step 10 of the test run on Page 32 to make sure the machine is correctly wired.

To correct phase polarity:

1.DISCONNECT MACHINE FROM POWER!

2.Open the control box and swap the connec- tions of any two incoming hot wires from the power source (see Figure 6).

 

POWER SOURCE

 

Swap Any

 

 

 

 

 

Two

A1

 

 

 

 

of These

 

 

 

 

 

 

 

 

 

Wires

1L1

3L2

5L3

NO13

 

Contactor

 

 

 

 

 

 

 

 

GROUND

 

2T1

4T2

6T3

NO14

 

 

 

 

 

 

ay

 

 

 

 

Figure 6. Wire connections to swap to correct

phase polarity.

Model G0442/G0601 (Mfg Since 8/10)

3.Secure the control box cover, then re-connect the machine to power.

4.Perform Step 10 of the test run on Page 32 to confirm that the power connections are correct.

—If the motor and impeller are still rotating in the wrong direction, contact our Tech Support at (570) 546-9663 for assistance.