B. Rear Vent
NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
NOTICE: Once the vent cap has been removed it CANNOT be reattached.
Figure 9.7
•Fold the tabs toward the center of the fire plug (90º) and remove the insulation gasket.
Figure 9.8
•Cut the metal retaining band and fold the sides out.
Figure 9.9
•Fold the center parts of the retaining band out and use to remove the vent cap.
Figure 9.10
•Discard the vent cap, remove and discard the insulation basket.
Figure 9.11
•Attach the first vent section (it will snap into place). Slide the insulation gasket onto the vent section, up against the appliance and over the tabs.
Heatilator • Novus NDV Series • | 37 |