5 Framing and Clearances
A. Select Appliance Location
When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.
B 1/2 in. (13 mm)
min. appliance to combustibles
Drywall
B
A
Top Vent
One 90° elbow
Horiz Term
A
G
Alcove
Installation
D
1/2 in. (13 mm) min.
Cappliance to combustibles
48 in.
(1219 mm)
maximum
A
Rear vent
One 45° elbow Horiz Term
1 in. (25 mm)
min. pipe to
combustibles
D
In addition to these framing dimensions, also reference the following sections:
•Clearances and Mantel Projections (Sections 3.C. and 3.D.)
•Vent Clearances and Framing (Section 6)
Rear Vent
One 90° elbow A Vert Term
E
1 in. (25 mm) |
|
min. pipe to | E |
combustibles |
No elbows
Horiz Term
A
Rear Vent |
|
Two 90° elbows | A |
Horiz Term |
F
C
F
Model |
| A | B | C | D | E | F | G |
NDV3630 | inches | 36 | 47 | 37 | ||||
| mm | 914 | 851 | 498 | 1102 | 1194 | 1353 | 940 |
NDV3933 | inches | 39 | 47 | 40 | ||||
|
|
|
|
|
|
|
|
|
| mm | 991 | 902 | 498 | 1102 | 1194 | 1353 | 1016 |
NDV4236 | inches | 42 | 47 | 43 | ||||
|
|
|
|
|
|
|
|
|
| mm | 1067 | 956 | 498 | 1102 | 1194 | 1353 | 1092 |
NDV4842 | inches | 48 | 47 | 49 | ||||
|
|
|
|
|
|
|
|
|
| mm | 1219 | 1064 | 498 | 1102 | 1194 | 1353 | 1245 |
Figure 5.1 Appliance Locations
18 | Heatilator • Novus NDV Series • |