1. Top Vent - Horizontal Termination - (continued)
ÎOne Elbow
V1
H1
Figure 7.4
ÎTwo Elbows
Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally.
Subtract
V1 Min | V1 Max | H1 Max. |
0* | - | 24 in./635 mm |
4 in./102 mm | - | 4 ft/1.22 m |
6 in./152 mm | - | 6 ft/1.83 m |
|
|
|
12 in./305 mm | - | 11 ft/3.35 m |
18 in./457 mm | - | 18 ft/5.49 m |
|
|
|
24 in./610 mm | - | 25 ft/7.62 m |
- | 25 ft/7.62 m (DVP) | 25 ft/7.62 m |
|
|
|
- | 23 ft/7.62 m (SLP) | 25 ft/7.62 m |
*You may install the elbow directly on top of the appliance (DVP only).
V1 min. | V1 max. | H1+H2 max. | H1+H2+H3 max. |
6 in./152 mm | - | 6 ft/1.83 m | - |
|
|
|
|
12 in./305 mm | - | 11 ft/3.35 m | 11 ft/3.35m |
18 in./457 mm | - | 18 ft/5.49 m | 18 ft/5.49m |
|
|
|
|
24 in./610 mm | - | 25 ft/7.62m | 25 ft/7.62m |
|
|
|
|
- | 25 ft/7.62 m (DVP) | 25 ft/7.62m | 25 ft/7.62m |
- | 23 ft/7.01 m (SLP) | 25 ft/7.62m | 25 ft/7.62m |
Installed
Vertically
H3
Installed
Horizontally
H1V1
H2 H2
Figure 7.5
Heatilator • Novus NDV Series • | 25 |