Hearth and Home Technologies NDV4842I B. Vent Components Diagrams continued, 12 in, 305 mm

Models: NDV3933IL NDV3036IL NDV4236L NDV4842L NDV4236I NDV3933L NDV4236IL NDV4842 NDV3630L NDV3933I NDV4842IL NDV4236 NDV4842I NDV3630 NDV3933 NDV3630I

1 84
Download 84 pages 46.5 Kb
Page 68
Image 68
12 in.

B. Vent Components Diagrams (continued)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

8in.

(203 mm)

Heat

Shield

15-1/8 in.

(384 mm)

 

 

 

 

 

 

 

Term Cap

Minimum

Maximum

 

 

 

 

 

 

 

Effective Length

Effective Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trap1

3-1/8 in.

4-5/8 in.

 

 

 

 

 

 

 

79 mm

117 mm

 

 

 

 

 

 

 

 

 

12 in.

 

 

 

Max

 

Trap2

5-3/8 in.

9-3/8 in.

 

 

(305 mm)

 

Effective

137 mm

238 mm

 

 

 

 

 

 

Length

 

 

 

 

 

 

 

 

 

 

DVP-TRAP

Horizontal Termination Cap

DVP-TRAP1

DVP-TRAPK1

DVP-TRAP2

DVP-TRAPK2

DVP-HPC1

DVP-HPC2

Figure 16.5 DVP Vent Components

68

Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08