4. Rear Vent - Vertical Termination (DVP only)

One Elbow

0 min.

6 ft (1.83 m) max.

12 ft (3.66 m) min.

60 ft (18.29 m) max.

Figure 7.14

Two Elbows

Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally.

Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed horizontally.

0 min.

12 ft (3.66 m) min.6 ft (1.83 m) max. 60 ft (18.29 m) max.

Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m)

Figure 7.15

Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08

31

Page 31
Image 31