Manuals
/
Hearth and Home Technologies
/
Household Appliance
/
Indoor Fireplace
Hearth and Home Technologies
NDV3630I, NDV4236IL Either cobrahead or SIT, 1 IPI Flame Patterns
Models:
NDV3933IL
NDV3036IL
NDV4236L
NDV4842L
NDV4236I
NDV3933L
NDV4236IL
NDV4842
NDV3630L
NDV3933I
NDV4842IL
NDV4236
NDV4842I
NDV3630
NDV3933
NDV3630I
1
15
84
84
Download
84 pages
46.5 Kb
12
13
14
15
16
17
18
19
<
>
Troubleshooting
Install
FAQ
Service Parts NDV3630 & NDV3630I
Vent Information and Diagrams
Warranty
Maintenance
A. Wiring Requirements
Symptom
Appliance Setup
Page 15
Image 15
(Either cobrahead or SIT)
Figure 3.1 IPI Flame Patterns
Figure 3.2 Standing Pilot Flame Patterns
Heatilator • Novus NDV Series •
4055-187
Rev F • 06/08
15
Page 14
Page 16
Page 15
Image 15
Page 14
Page 16
Contents
D DO
Models
What to do if you smell gas
Owner’s Manual
Please retain this owner’s manual for future reference
A. Congratulations
Homeowner Reference Information
Read this manual before installing or operating this appliance
User Guide
Table of Contents
Installer Guide
Safety Alert Key
Reference Materials
14 Appliance Setup
Troubleshooting
Î = Contains updated information
1 Year Limited Warranty
B. Limited Lifetime Warranty
Gas Appliance Fireplace Limited Lifetime Warranty
Limited Lifetime Warranty
B. Tempered Glass Specifications
D. High Altitude Installations
1 Listing and Code Approvals
A. Appliance Certification
MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided
G. Requirements for the Commonwealth of Massacusetts
Installation of Carbon Monoxide Detectors
Exemptions
B. Your Fireplace
A. Gas Fireplace Safety
User Guide
2 Operating Instructions
D. Clear Space
F. Fixed Glass Assembly
G. Remote Controls, Wall Controls and Wall Switches
C. Fan Kit optional
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
Ignition IPI
or explosion may result causing property damage
Ignition
TO TURN OFF GAS TO APPLIANCE
WARNING RISK OF FIRE
J. Standing Pilot
SOLUTIONS
L. Frequently Asked Questions
K. After Appliance is Lit
ISSUE
Remote Control
3 Maintenance and Service
A. Maintenance Tasks-Homeowner
Glass Cleaning
Logs
B. Maintenance Tasks-Service Technician
Gasket Seal and Glass Assembly Inspection
Venting
Either cobrahead or SIT
Figure 3.1 IPI Flame Patterns
Figure 3.2 Standing Pilot Flame Patterns
Figure 4.1 Typical Appliance System
Installer Guide
Getting Started
A. Typical Appliance System
B. Design and Installation Considerations
C. Tools and Supplies Needed
D. Inspect Appliance and Components
Figure 5.1 Appliance Locations
5 Framing and Clearances
A. Select Appliance Location
Model
C. Clearances
B. Constructing the Appliance Chase
D. Mantel and Wall Projections
Mantels
Mantel Legs or Wall Projections
DO NOT pack air space with insulation or other materials
6 Termination Locations
A. Vent Termination Minimum Clearances
Fire Risk Maintain vent clearance to combustibles as specified
Figure 6.5 Minimum Clearances for Terminations
B. Vent Table Key
7 Vent Information and Diagrams
A. Approved Pipe
D. Measuring Standards
E. Vent Diagrams
1. Top Vent - Horizontal Termination Two 45 Elbows
4 ft min 1.22 m 25 ft max. 7.62 m
Î Two Elbows
1. Top Vent - Horizontal Termination - continued
V1 H1
Î One Elbow
12 in./305 mm
1. Top Vent - Horizontal Termination
continued
Î Three Elbows
Two Elbows
2. Top Vent - Vertical Termination
Î Install Top Vent Flue Visor - No Elbow Configura- tions
No Elbow
Three Elbows
2. Top Vent - Vertical Termination - continued
18 in. 457 mm max
3. Rear Vent - Horizontal Termination DVP only
No Elbow
One 45 Elbow
Two Elbows
V1 H2
3. Rear Vent - Horizontal Termination DVP only - continued
Installed Horizontally H3H2
Two Elbows
4. Rear Vent - Vertical Termination DVP only
One Elbow
0 min 6 ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max
4. Rear Vent - Vertical Termination DVP only - continued
Three Elbows
0 min 6 ft 1.83 m max 12 ft 3.66 m min 60 ft 18.29 m max
Between ceiling firestops Between wall shield firestops
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles
B. Wall Penetration Framing
C. Install the Ceiling Firestop
D. Install Attic Insulation Shield
Flat Ceiling Installation
Vaulted Ceiling Installation
A. Top Vent
9 Appliance Preparation
NOTICE Once the vent cap has been removed it CANNOT be reattached
B. Rear Vent
Framing and other combustible materials
C. Secure and Level the Appliance
WARNING! Risk of Fire! Prevent contact with
Sagging or loose insulation Insulation backing or plastic
Assemble Pipe Sections
10 Installing Vent Pipe
Î A. Assemble Vent Sections DVP only
Attach Vent to the Firebox Assembly
Î B. Assemble Vent Sections SLP Pipe Only
Î C. Assemble MI Sections DVP only
Cut from this end outer Cut from this end inner
Only outer pipes are sealed, sealing the inner flue is not required
Î D. Assemble Slip Sections
Î F. Disassemble Vent Sections
Î E. Secure the Vent Sections
Î G. Install Decorative Ceiling Components SLP only
Flashing
Î H. Install Metal Roof Flashing
Pipe
Caulk
Apply Sealant Top & Partial Sides
Î I. Install RF4-8
Silicone Sealant top of boot Shingles Trimmed
Secure with 4 screws no longer than 1/2 in./13 mm SLP-FS
K. Assemble and Install Storm Collar
J. Install Vertical Termination Cap
Heat Shield Requirements for Horizontal Termi- nation
Î L. Install Heat Shields and Horizontal Termi nation Cap
Install Horizontal Termination Cap
1-1/2 38 mm minimum overlap of flue telescoping section is required
Failure to maintain overlap may cause overheating and fire
C. Gas Connection
11 Gas Information
A. Fuel Conversion
B. Gas Pressure
D. Optional Accessories Requirements
A. Wiring Requirements
B. Standing Pilot Ignition System Wiring
C. Intellifire Ignition System Wiring
E. Electrical Service and Repair
110 VAC to wall switch
F. Junction Box Installation
G. Wall Switch Installation for Fan Optional
NOTICE DO NOT wire
Mantel Legs or Wall Projections
13 Finishing
A. Mantel and Wall Projections
Mantels
B. Facing Material
E. Clean the Appliance
14 Appliance Setup
B. Open Front Screen Assembly
D. Remove Fixed Glass Assembly
J. Remove Screen Protector
G. Place the Rockwool
H. Place the Lava Rock
I. Place the Vermiculite
K. Unpackage the Hood & Floor Cover
L. Install Hood
Removing Fixed Glass Assembly
M. Install Floor Cover
N. Fixed Glass Assembly
O. Close the Screen Assembly
P. Air Shutter Setting
Figure 14.14 Adjusting Air Shutter
Close Open
Possible Causes
15 Troubleshooting
A. Standing Pilot Ignition System
Symptom
Corrective Action
Troubleshooting continued
Symptom
Possible Cause
Corrective Action
B. Intellifire Ignition System
Symptom
Possible Cause
Corrective Action
Intellifire Ignition System - continued
Symptom
Possible Cause
A. Appliance Dimension Diagram
16 Reference Materials
Model
Assembled Height 24 in./610 mm Diameter 10 in./254 mm
B. Vent Components Diagrams
Height/Length
DVP Pipe
RF6M
B. Vent Components Diagrams continued
DVP-HSM-B
Extended Heat Shield
DVP-HPC High Performance Cap Figure 16.4 DVP Vent Components
B. Vent Components Diagrams continued
DVP-TB1 Basement Vent Cap
DVP-TVHW Vertical Termination Cap High wind
Effective
B. Vent Components Diagrams continued
12 in
305 mm
DVP-HRC-ZC-SS Not approved for NDV4842
B. Vent Components Diagrams continued
Î DVP-TRAP to DVP-HPC Side Filler Kit
DVP-HRC-SS Not approved for NDV4842
Length
B. Vent Components Diagrams continued
Effective
Height
SLP-CCS-BK
B. Vent Components Diagrams continued
PVK-80 Power Vent
Î SLK-SNKD
Service Parts NDV3630 & NDV3630I
Parts
Heatilator
Rev F 06/08
Service Parts NDV3630 & NDV3630I
Standing Pilot Valve
IPI Valve
Heatilator Novus NDV Series 4055-187 Rev F 06/08
Service Parts NDV3933 & NDV3933I
Heatilator Novus NDV Series
Service Parts NDV3933 & NDV3933I
Standing Pilot Valve
IPI Valve
Heatilator Novus NDV Series 4055-187 Rev F 06/08
Service Parts NDV4236 & NDV4236I
Heatilator Novus NDV Series
Service Parts NDV4236 & NDV4236I
Standing Pilot Valve
IPI Valve
Heatilator Novus NDV Series 4055-187 Rev F 06/08
Service Parts NDV4842 & NDV4842I
Heatilator Novus NDV Series
Service Parts NDV4842 & NDV4842I
Standing Pilot Valve
IPI Valve
Model #
D. Optional Components
Model #
Description
Description
Model #
Description
Model #
Heatilator Novus NDV Series 4055-187 Rev F 06/08
This page intentionally left blank
Heatilator Novus NDV Series 4055-187 Rev F 06/08
This page intentionally left blank
DO NOT DISCARD THIS MANUAL
E. Contact Information
and maintenance
installation and operation